PX-D110M TECHLITE™ MILITARY GRADE LED/LASER TEST SET
Availability: Call For Availability
The TECHLITE™ PX-D110M test sets allow technicians to perform precise optical measurements in the field. When operated in absolute power mode, the B220M meter is used to determine the level of optical power being emitted from a transmitter. In relative mode, it is used with the included source to perform fiber loss measurements or splice tuning operations.
TECHLITE™ meters and sources were designed to be rugged. As with all Photonix test instruments, the internal circuitry is housed within an aluminum extrusion with high impact rubber bumpers. In addition, the instruction guide is fully laminated to make it weather-resistant and virtually tear-proof.
The TECHLITE™ meter, in relative measurement mode, will store the zero reference reading for all four wavelengths independently in non-volatile memory. This allows all zero references to be taken at one time and also allows the unit to be turned off while moving between locations preserve battery life. Also in relative mode, the meters will also display a 1dB analog typedeviation pointer and an mini-display for real time splice tuning.The TECHLITE™ meters utilize a graphic LCD screen to createunusually large and easy to read numbers as graphics to indicatepower levels.
The included TECHLITE™ PX-C202M LED source offers advanced temperature and coupling stability as well as enhanced CPR performance to provide superior test accuracy. Both the PX-C202M and the PX-C205M LASER sources, offer the ability to operate one or both outputs simultaneously in either CW, 30Hz, 500Hz, or 2kHz modulation for use with leak detectors or fiber identifiers.
The units are powered by either four AA alkaline batteries or an AC wall pack with four AA NiMH cells (both the wall pack and NiMH cells are included). In addition to standard charge mode, the units feature an emergency quick charge mode that allows the user to charge the batteries in approximately 4 hours. A 20 minute auto power off feature is also switch selectable from the top panel on all units.
Power Meter PX-B220M | LED SOURCE PX-C202M | LASER SOURCE PX-C205M | |||
Parameter | Value | Parameter | Value | Parameter | Value |
Wavelength | 800-1600nm | Wavelength | 850,1300nm (+/-30nm) | Wavelength | 1310,1550nm(±30nm) |
Calibration Points | 850,1300,1310,1550nm | Fiber Size | 62.5/125 (max) | Line Width | 5nm |
Power Range | +3 to -55dBm | Port Style | ST | Port Style | ST |
Resolution | 0.01dB | Source Pmin | -21dBm | Pmin (9/125) | -10.0dBm CW |
Accuracy | ±0.25dB | Stability(4hr) | ±0.10dB | Stability | ±0.10dB (4hr) |
Linearity (+3 to -40dBm) | ±0.30dB | Stability(0-50°C) | ±0.50dB | Stability | 2410.75dB(0-50°C) |
Linearity (-40 to -55dBm) | ±0.50dB | Repeatability | ±0.10dB | Repeatability | ±0.20dB |
Repeatability | ±0.10dB | Bandwidth | 35(850nm)/170(1300nm) | Bandwidth | 5nm(1310,1550nm) |
Detector | Ge | CPR at 850nm | 25-29dB +/-1.0 | Modulation | CW,30Hz,500Hz, 2kHz |
Operation Modes | dB,dBm, Watts | CPR at 1300nm | 21-25dB +/-0.5 | Warmup Time | 15 minutes |
Light Susceptibility | <-55dBm | Modulation | CW,30Hz,500Hz, 2kHz | ||
Warmup Time | 15 minutes | ||||
ALL UNITS | |||||
Parameter | Value | Parameter | Value | Parameter | Value |
Operating Temp | 0°C to 50°C | Storage Temp | -20°C to 60°C | Humidity | 10% - 90% non-cond. |
Line Power | 110/220VAC, 50-60Hz | Battery Power | NiMH 4-AA or Alkaline | Battery Life | 10 Hours(typ) |
Charge Time | 12 Hours(typ) Trickle | Charge Time | 4 Hours(typ) Quick | Performance Spec | MIL-T-28800 |
~ Meter: 850nm / 1300nm / 1310nm / 1550nm with interchangeable meter adapters
~ LED Source: 850nm/1300nm
~ LASER Source: 1310nm/1550nm
~ Reel style connector cleaner
~ SC,FC,LC or ST adapters
~ SMF patch cords ST-FC, ST-SC, ST-LC
~ MMF patch cords ST-FC, ST-SC, ST-LC
~ Crush resistant aluminum bodies
~ 0.01 dB Meter resolution
~ Controlled LED CPR operation
~ Built in quick charger
~ Sealed waterproof carry case
~ Two year warranty